Contact us

Contact us

Email
aikred@accord-power.com
Call Us
0086 559 2621813
Mon - Sat 9.00 - 18.00 Sunday Closed
Weiyi Road, Shexian Recycling Economic Park, Huangshan City, Anhui Province, China
Contact us
aikred@accord-power.com
0086 559 2621813
Facebook
Twitter
Linkedin
Reasons for insufficient 24-hour battery backup time for ups
2024-03-16
There are various reasons for the lack of 24-hour battery backup time for

UPS (Uninterruptible Power Supply). First, the performance and quality of the battery itself is a key factor affecting the standby time. If the battery is aging, damaged, or has insufficient capacity, its power supply capability will naturally decrease, resulting in a shorter standby time. Second, the load of the UPS system is also an important factor affecting the standby time. If the load is too heavy, the battery needs to provide more power to support the system operation, which will consume more power and thus reduce the standby time. In addition, environmental factors such as temperature and humidity can also affect battery performance and life, which in turn affects standby time. Finally, the design and configuration of the UPS system can also have an impact on standby time. If the system is not properly designed or configured, it may result in the batteries not being able to give full play to their performance, thus affecting the standby time. Therefore, in order to ensure that the UPS system can provide sufficient standby time, users need to select batteries with excellent performance and reliable quality, and reasonably configure and use the UPS system. At the same time, it is also very important to check and maintain the batteries on a regular basis.


Uninterruptible Power Supply (UPS) is a power electronic system that contains an energy storage device (usually batteries), and its main function is to provide continuous and stable power for critical equipment through the internal energy storage device in the event of an interruption in the main power supply. Many users have a need for long battery backup for their UPS, especially in areas of unstable power supply, and expect the UPS to provide at least 24 hours of support in the event of a power outage. However, users sometimes find that the actual standby time falls far short of expectations. In this article, we will analyze in detail the common causes of insufficient UPS 24-hour battery backup time.

image.png


1. Inadequate Battery Capacity Calculation

The calculation of battery capacity is one of the key factors in determining the amount of time a UPS can provide continuous power. If the initial design is not calculated accurately or the size of the required load is not properly evaluated, there is a risk that the actual battery standby time will be lower than expected. Factors that need to be considered for an uninterrupted power provider include the size of the load, the rated capacity of the batteries, and the overall efficiency of the system. The design needs to allow for sufficient capacity and redundancy to meet actual operational consumption. Inadequate capacity calculations can lead directly to insufficient standby time.

2. Battery aging and performance degradation

All batteries gradually age and lose capacity during use. The chemistry of batteries dictates that they have a certain lifespan, and over-discharging, charging, and poor environmental conditions (e.g., high or low temperatures) can accelerate the degradation of battery performance. Battery performance degradation is one of the most common reasons for understanding the lack of UPS standby time. Over time, the effective capacity of a battery decreases, even under normal conditions of use and care, resulting in an inability to provide power support long enough for connected equipment.

3. Problems with the charging system

The charging system of a UPS is critical to ensure that the batteries are always in optimal condition. An effective charging system should be able to charge the batteries quickly and accurately while avoiding over- or under-charging. If the charging system malfunctions or if it is improperly configured, it may result in a failure to fully charge the battery or an unbalanced charge. For example, some chargers may automatically stop charging after the battery has been charged to a certain level, failing to charge the battery to the capacity needed to meet a 24-hour standby. In addition, improper charging current and voltage settings may also result in poor battery performance, further reducing the UPS standby time.

4. Improper system configuration and maintenance

In addition to battery-related issues, the configuration and maintenance of the UPS system itself can have a significant impact on standby time. This includes hardware failures, improper firmware or software settings, and lack of regular system checks and maintenance. An optimized and well-maintained system makes better use of battery resources and thus increases standby time. For example, unnecessary energy consumption in a system that is not properly configured to turn off or reduce its power consumption can unnecessarily reduce standby time.

5. Additional Loads and Environmental Factors

The potential for increased loads over time may not have been adequately considered when designing or installing the UPS system. As business expands or technology is upgraded, additional equipment may be plugged into the UPS system, causing the originally calculated standby time to become insufficient due to increased load. Environmental factors such as temperature, humidity, and dust can affect the performance of the UPS system and its batteries. Excessively high or low temperatures can affect the discharge efficiency and life of the batteries, and humidity and dust can lead to equipment failures that can affect the normal operation of the UPS.

6. Difference between expected and actual

In some cases, due to a lack of understanding of the UPS system, the user's expectation of standby time may be outside the actual design range of the product. Reasons for this discrepancy may include high expectations, misinterpretation of product specifications, or errors in load calculations. Users must have a clear understanding of the performance parameters of UPS equipment and make a reasonable selection based on actual needs. Before purchasing, consult with a professional and conduct a detailed load assessment and capacity planning based on the actual situation.

7. Influence of combined factors

In fact, the cause of insufficient UPS backup battery time is often the result of a combination of factors. For example, battery degradation and charging system problems may co-exist, or environmental factors plus poor usage habits may act together on battery life. In order to ensure that a UPS system provides adequate standby time, each of the factors mentioned above needs to be thoroughly scrutinized and monitored in real time. The battery backup time of a UPS system can be maximized through regular system checks, replacement of aging batteries, maintenance of suitable environmental conditions, and proper planning for future power needs.

In summary, ensuring that a UPS system is capable of providing 24 hours of battery backup time is a comprehensive endeavor that requires proper design, planning, maintenance and management. Understanding the various factors that affect the standby time allows you to take appropriate measures to ensure that the UPS can provide uninterrupted power support to meet demand at critical times.